Circuit Breaker Testing

Camlin Energy's PROFILE P3 provides on-site Circuit Breaker Testing through ‘first trip’ profiling. This enables condition-based maintenance to reduce operating costs and extend asset life.

Preventing slow Circuit Breaker Trip: the challenge for asset managers

A slow circuit breaker trip, due to aging or poor maintenance can cause major problems for network operators, taking customers off supply. And a delay in the circuit breaker trip can cause high current faults to ‘cascade’ across the network, leading to:

  • Plant damage
  • Safety risks to operational staff
  • Costly financial penalties

Conventional Circuit Breaker timing tests, which require the circuit breaker to be removed from service, don't provide an accurate assessment of the Circuit Breaker condition. Defects which may lead to slow trip operations are often temporarily cleared during the first Circuit Breaker operation, making it difficult to assess how the Circuit Breaker would perform in real-world fault conditions.

Profile Test Antoine Logos Removed

PROFILE P3 Benefits

Cost icon

Reduced Circuit Breaker maintenance costs

Drives cost-effective maintenance strategies for asset managers based on condition-based circuit breaker assessment

Icons coral 105 Foresight

Intuitive visual profiling

Enables rapid onsite analysis of circuit breaker defects by comparing first trip or close profile with subsequent circuit breaker operations

Costly penalties icon

Avoid costly Regulatory penalties

Pre-empt problems caused by slow circuit breaker trip operation causing supply loss, costly network equipment damage and potential penalties due to CI/CML.

Icons coral 105 Cog solution

Extended circuit breaker asset life

Quick, simple trending of key circuit breaker key parameters allows operators to anticipate maintenance requirements and extend asset life.

Key features

  1. Powerful Onsite Analysis: PROFILE P3 can display and overlay up to 4 records in graphical form. This enables quick onsite analysis of potential circuit breaker defects by comparing a first trip or close profile to subsequent circuit breaker operations.
  2. Combined Protection Relay and Circuit Breaker Online Test: An enhanced version of the software enables both the protection relay and circuit breaker trip times to be captured.
  3. Multi-shot Mode: With this function PROFILE P3 is able to re-arm and capture multiple circuit breaker operations. This can be used for monitoring a circuit breaker during faults or SCADA initiated operations.
  4. Automated Comparison Function: This provides a clear pass/fail (green/red) indication by determining if the key parameters – Buffer, Acon, Mcon are outside user set tolerances between the first, second and third trip operations.

Profile Test

PROFILE P3 Documentation

Brochure

See the Complete Picture

Integrated with PROFILE P3, REPLAYPRO software for PC is a powerful analysis tool that combines detection of circuit breaker defects with trending of performance against key parameters from profile records imported from the system. REPLAYPRO can be hosted on a central server, allowing circuit breaker profiling data to be shared with other uses across your organisation.

REPLAYPRO software is an integral part of the PROFILE P3 system enabling efficient profile record storage, retrieval and analysis. It provides the critical link between the system and those within the organisation who need to access the data in order to effectively manage their assets.

Replay Pro 2 817 x 460